Gas generators for chromatography
NeoCHROM HMG series hydrogen generators
Features and benefits:
- SPE solid polymer electrolyte technology (solid polymer electrolyte);
- efficient direct electrolysis of pure water without alkali;
- high-quality ion exchange membrane;
- an O-ring (with low sulfur content) is used inside the instrument to improve gas quality;
- gas quality and stable chromatographic baseline; suitable for FID, NPD and MS detectors;
- integrated gas pressure and flow control;
- automatic water level monitoring and shutdown when water is insufficient;
- electrolyzer protection for extended service life;
- compatible with any type of gas chromatograph from any manufacturer (connections and communication outputs are adapted to NeoCHROM GC instruments by default);
| Technical parameter | HMG-300* | HMG-500** | HMG-1000*** |
|---|---|---|---|
| Hydrogen purity | 99.999% | 99.999% | 99.999% |
| Outlet flow | 300 mL/min | 500 mL/min | 1000 mL/min |
| Outlet pressure | 0-0.4 MPa | 0-0.4 MPa | 0-0.4 MPa |
| Pressure compensation | 0.01 MPa | 0.01 MPa | 0.01 MPa |
| Power supply | 150 W | 250 W | 250 W |
| Dimensions, weight | 360×300×140 mm, 14 kg | 400×360×220 mm, 14 kg | 400×360×220 mm, 14 kg |
* recommended for supplying ionization detectors alone or together with carrier gas flow through a capillary column shorter than 50 m, provided that the analytical method uses a split ratio no greater than 100.
** recommended for supplying ionization detectors alone or together with carrier gas flow through a capillary column shorter than 50 m, provided that the analytical method uses a split ratio no greater than 250-300
*** recommended for applications requiring high gas flow rates
NeoCHROM NG series nitrogen generator
Features and benefits:
- automatic pressure and flow display; automatic constant pressure and current control; nitrogen flow can be adjusted automatically to match demand;
- advanced technology: membrane separation is used in the electrolytic cell; a PCAN support and precious-metal catalyst are used in the catalytic layer, providing high catalytic efficiency, high gas output and high nitrogen purity;
- the electrolytic cell undergoes more than 100 hours of ageing testing at high voltage and current before delivery, improving its operational stability.
- low moisture content of the generated nitrogen: membrane separation with ultrahigh molecular permeability and a metal-polymer drying device reduce initial moisture;
- two adsorption systems are used, including a trace oxygen removal agent that requires no activation, further lowering the nitrogen dew point and improving purity;
- easy operation: no need to transport or handle purification cylinders; simply switch the unit on to generate nitrogen. Continuous or intermittent operation provides stable nitrogen production without a reduction in flow.
- safe and reliable: equipped with a sensitive and reliable automatic alkali protection device.
| Parameter | NG-300* | NG-500** | NG-1000*** |
|---|---|---|---|
| Nitrogen purity | Oxygen <3 ppm | Oxygen <3 ppm | 99.999% |
| Outlet flow | 0-500 mL/min | 0-500 mL/min | 0-1000 mL/min |
| Outlet pressure | 0-0.4 MPa | 0-0.4 MPa | 0-0.4 MPa |
| Pressure fluctuations | < 0.003 MPa | < 0.003 MPa | < 0.003 MPa |
| Power supply | 220V±10% , 110V±10% | 220V±10% , 110V±10% | 220V±10% , 110V±10% |
| Power consumption | 60 W | 100 W | 150 W |
| Operating conditions | Temperature 0-45 ℃, relative humidity: 85% |
Temperature 0-45 ℃, relative humidity: 85% |
Temperature 0-45 ℃, relative humidity: 85% |
| Dimensions, weight | 370*180*330 mm, 11 kg | 370*180*330 mm, 11 kg | 370*180*330 mm, 20 kg |
* recommended for supplying ionization detectors alone or together with carrier gas flow through a capillary column shorter than 50 m, provided that the analytical method uses a split ratio no greater than 100.
** recommended for supplying ionization detectors alone or together with carrier gas flow through a capillary column shorter than 50 m, provided that the analytical method uses a split ratio no greater than 250-300
*** recommended for applications requiring high gas flow rates